100% tested before shipping in accordance with ISO 15738.
Production test tollerances -5 +10% - Functional tollerances for user -5 +20% INSTALLATION 1a. HOLE REQUIRED FOR RV70 VALVE INSTALLATION = D70 +/-0,5 mm
1b. HOLE REQUIRED FOR RVG70 VALVE INSTALLATION = D41 +/-0,5 mm
2. TIGHTENING TORQUE = 30 Nm
THE VALVE ASSEMBLY SHOULD BE RE-TORQUED AFTER AT LEAST 12 HOURS
3. THE USERS RESPONSIBILITY TO ENSOURE THAT ANY FLUIDS USED DURING THE
INSTALLATION OR OPERATION ARE COMPATIBLE WITH THIS VALVE
4. PRESSURES SETTING AVAILABLE IN THE TABLE ATTACHED

ItemPart numberCalibrationColorOpeningClosing
Pax 1000 mbarpsi Pax 1000 mbarpsi
VAKA080173180/150Rosso/Red18.0 1802.6 15.0 1502.2
KA080174200/170Nero/Black 20.02002.917.0 1702.5
KA080175230/200Grigio/Grey 23.02303.320.0 2002.9
KA080176255/225Verde/Green 25.5 2553.722.5 2253.3
KA080177280/250Blu/Blue 28.0 2804.025.0 2503.6